Póngase en contacto con BBP

Formulario de contacto

Total Dynamic Head (TDH) Calculator

Compute the required pump head for your farm irrigation system. Add static elevation, operating pressure, and friction loss to get TDH in meters.

Formula: TDH = Static Elevation + (PSI × 0.703) + Suction Friction + Discharge Friction

1 PSI ≈ 0.703 m head (water, SG=1.0). For sediment-laden or saline water, correct for specific gravity. Suction friction at 5 m/s velocity in 50 mm pipe ≈ 0.08 m per meter of pipe — refer to ANSI/HI 14.6 or a Moody chart for precise values.