Total Dynamic Head (TDH) Calculator

Compute the required pump head for your farm irrigation system. Add static elevation, operating pressure, and friction loss to get TDH in meters.

Formula: TDH = Static Elevation + (PSI × 0.703) + Suction Friction + Discharge Friction

1 PSI ≈ 0.703 m head (water, SG=1.0). For sediment-laden or saline water, correct for specific gravity. Suction friction at 5 m/s velocity in 50 mm pipe ≈ 0.08 m per meter of pipe — refer to ANSI/HI 14.6 or a Moody chart for precise values.