Get in Touch with BBP
Self-Priming Sewage Pump
Self-Priming Non-Clog Sewage & Trash Pump — AZX Series by BBP
Why Site Managers Replace Submersibles With Self-Priming AZX Pumps
AZX goes beyond generic self-priming designs with three architectural choices matched to municipal and industrial sewage:
AZX Model Range — 36 Configurations From 3 to 800 m³/h
Thirty-six factory-catalogued models of AZX operate at either 1450 or 2900 rpm drive speed, within the flow and head envelope required by municipal lift stations, industrial process water or construction dewatering. They are identified directly from the envelope:
Model Designation — Read the Spec from the Name
Decision Matrix — Pick a Series by Flow and Head
Complete Performance Specifications
| Model | Flow m³/h (GPM) | Head m (ft) | Speed rpm | Power kW (HP) | Efficiency % | NPSHr m | Suction H m | Inlet in |
|---|---|---|---|---|---|---|---|---|
| 25-8-15 | 8 | 15 | 2900 | 3.0 | 45 | 2.0 | 5.5 | 1 |
| 32-5-20 | 5 | 20 | 2900 | 3.0 | 43 | 2.5 | 5.5 | 1.25 |
| 32-9-30 | 9 | 30 | 2900 | 4.0 | 46 | 2.5 | 5.5 | 1.25 |
| 32-10-20 | 10 | 20 | 2900 | 3.0 | 45 | 2.5 | 5.5 | 1.25 |
| 32-18-30 | 18 | 30 | 2900 | 5.5 | 48 | 3.0 | 5.5 | 1.25 |
| 40-10-20 | 10 | 20 | 2900 | 3.0 | 50 | 2.5 | 5.5 | 1.5 |
| 40-20-20 | 20 | 20 | 2900 | 4.0 | 52 | 3.0 | 5.5 | 1.5 |
| 40-15-35 | 15 | 35 | 2900 | 5.5 | 48 | 3.0 | 5.5 | 1.5 |
| 50-10-20 | 10 | 20 | 2900 | 3.0 | 55 | 2.5 | 5.5 | 2 |
| 50-20-20 | 20 | 20 | 2900 | 4.0 | 58 | 3.0 | 5.5 | 2 |
| 50-16-20 | 16 | 20 | 2900 | 4.0 | 56 | 3.0 | 5.5 | 2 |
| 50-20-12 | 20 | 12 | 2900 | 3.0 | 58 | 3.0 | 6.0 | 2 |
| 50-26-30 | 26 | 30 | 2900 | 7.5 | 60 | 3.5 | 5.5 | 2 |
| 65-25-30 | 25 | 30 | 2900 | 7.5 | 62 | 3.5 | 5.5 | 2.5 |
| 65-25-40 | 25 | 40 | 2900 | 11 | 60 | 4.0 | 5.0 | 2.5 |
| 65-40-20 | 40 | 20 | 1450 | 5.5 | 65 | 3.5 | 6.5 | 2.5 |
| 65-40-25 | 40 | 25 | 1450 | 7.5 | 66 | 4.0 | 6.5 | 2.5 |
| 65-65-25 | 65 | 25 | 2900 | 11 | 68 | 4.0 | 5.5 | 2.5 |
| 65-66-25 | 66 | 25 | 2900 | 11 | 68 | 4.0 | 5.5 | 2.5 |
| 80-50-35 | 50 | 35 | 2900 | 15 | 68 | 4.5 | 5.0 | 3 |
| 80-50-60 | 50 | 60 | 2900 | 22 | 62 | 5.5 | 4.5 | 3 |
| 80-65-25 | 65 | 25 | 2900 | 11 | 70 | 4.5 | 5.5 | 3 |
| 80-40-16 | 40 | 16 | 1450 | 5.5 | 70 | 3.5 | 6.5 | 3 |
| 80-80-35 | 80 | 35 | 2900 | 22 | 70 | 5.0 | 5.0 | 3 |
| 100-100-30 | 100 | 30 | 1450 | 18.5 | 72 | 4.5 | 6.0 | 4 |
| 100-80-20 | 80 | 20 | 1450 | 11 | 72 | 4.0 | 6.5 | 4 |
| 100-100-15 | 100 | 15 | 1450 | 11 | 74 | 4.0 | 6.5 | 4 |
| 125-120-20 | 120 | 20 | 1450 | 18.5 | 74 | 4.5 | 6.5 | 5 |
| 150-180-38 | 180 | 38 | 1450 | 37 | 74 | 5.5 | 5.5 | 6 |
| 150-180-30 | 180 | 30 | 1450 | 30 | 75 | 5.0 | 6.0 | 6 |
| 150-180-20 | 180 | 20 | 1450 | 22 | 75 | 4.5 | 6.5 | 6 |
| 200-280-28 | 280 | 28 | 1450 | 45 | 75 | 5.5 | 5.5 | 8 |
| 200-280-14 | 280 | 14 | 1450 | 22 | 75 | 4.0 | 6.5 | 8 |
| 250-420-14 | 420 | 14 | 1450 | 37 | 75 | 4.5 | 6.5 | 10 |
| 300-800-14 | 800 | 14 | 1450 | 55 | 75 | 5.0 | 6.5 | 12 |
| 80-80-20 | 80 | 20 | 1450 | 11 | 72 | 4.0 | 6.5 | 3 |
AZX vs Submersible Sewage Pump — 8-Dimension Data Comparison
Below is a data-driven comparison across eight operational dimensions. Absolutely no "high/medium/low" judgments--only specific numbers, specific units, and specific tradeoffs.
Gold-Tier ROI Benchmark — Independently Documented
Proven In Municipal, Industrial & Aquaculture Applications
Municipal Sewage Lift Stations
AZX 80-65-25 · 65 m³/h
Food & Beverage Wastewater
AZX 50-20-25 · 316L option
Paper & Pulp Effluent
AZX 100-100-15 · 100 m³/h (440 GPM)
Chemical Process Transfer
AZX 65-40-20 · SS316 body
Construction & Mining Dewatering
AZX 150-180-20 · portable skid
Aquaculture & Pond Management
AZX 40-15-20 · low-shear
Power Plant Cooling Slurry
AZX 200-280-14 · 280 m³/h
Procurement Factors — What to Specify When Requesting a Quote
Factors That Drive AZX Pricing
Pump series model
Each DN series has a different casting volume, machining envelope, and shaft diameter. Larger models carry more material and machining time per unit.Material of construction
Gray iron body is standard; stainless steel wetted parts (SS304, SS316, SS316L) step pricing up according to raw material cost at time of order.Mechanical seal grade
Standard mechanical seal, silicon carbide faces for abrasive duty, or double-seal arrangement for regulated chemical service.Motor and drive option
Bare pump for customer-supplied drive, IE3 electric motor, diesel engine drive, or VFD-ready configuration.Packaging specification
Domestic crating, export-grade plywood, or fumigated ISPM-15 compliant case for regulated destinations.Inco terms
EXW Beijing, FOB Tianjin, CIF destination port, or DDP full landed cost—each shifts the quotation structure.Factors That Drive Lead Time
MOQ & Payment:
self-priming:
AZX Model Selector — Match Your Duty Point to 1 of 36 Models
Enter your required flow and head. The tool matches your duty point against the AZX Series factory catalog and returns the three closest model matches ranked by efficiency at your operating point.
Duty Point
Model Matches
Your flow/head combination sits outside the AZX Series envelope (3–800 m³/h, 12–60 m head). Our engineering team can design a custom configuration or pair multiple pumps in series or parallel.
Request factory acceptance test report + quotation:
Get Quick Quote →Matches ranked by efficiency at your duty point. All figures are from the AZX factory catalog 2024 revision and reference ISO 9906 Grade 2B hydraulic acceptance test results.
Self-Priming Sewage Pump: Guides & Articles
Technical guides on selection, sizing, operation and maintenance.

Self-Priming Pumps for Construction Site Dewatering: A Contractor’s Selection Guide
How contractors choose, rent, or buy self-priming pumps for construction dewatering — methods, permits, vendor checklist, and rent-vs-buy math.
Read Article →![Self-Priming Pump How It Works, Types & Selection [2025]](https://bbpmfg.com/wp-content/uploads/2026/04/Self-Priming-Pump-How-It-Works-Types-Selection-2025-768x512.png)
Self-Priming Pump: How It Works, Types & Selection [2025]
Learn how self-priming pumps work, key types (centrifugal, diaphragm, jet), top applications, and how to choose the right pump.
Read Article →FAQ — Engineering Questions Before You Specify AZX
How does a self-priming sewage pump work — and when does it beat a submersible?
What solids size can an AZX pump pass through?
Can AZX pumps run dry without damage?
What is the maximum suction lift of AZX models?
Are AZX pumps suitable for corrosive chemicals?
How long does initial priming take, and is re-priming automatic?
What certifications do AZX pumps carry?
Do AZX pumps require a foot valve or check valve in the suction line?
I've had self-priming pumps lose prime after a year in sewage service — does AZX have the same problem?
"Gorman-Rupp pumps are trash" — I've seen that comment in wastewater operator forums. How is AZX different from generic copycat self-priming pumps?